Model 200 serial interface

From Bitchin100 DocGarden
Jump to navigationJump to search

Overview

The BASIC ROM provides access to the serial port. BASIC ROM support is well documented elsewhere. This article covers direct use of the 80C52 on the Tandy 200.

Configuration

Before the serial port can be used, it must be configured both for serial word format (data bits, stop bits, and parity) and baud rate.

Select RS232 Port

At any given time, either the internal modem or the external RS232 connector may be connected to the UART. This is controllable through software.

For RS232 access, 8155 port B $B2, bit #3 must be set to 0.

For Modem access, 8155 port B $B2, bit #3 must be set to 1.

Note that $B2 is shared with other functions, including power control.

Serial Word Format

Port $C0 controls the mode configuration and command register.

Mode configuration (Asyncronous)

Bit Function Settings
0-1 Baud rate devisor 00=*
01=1x
10=16x
11=64x
2-3 Character Length Select Bits:
00 → 5
01 → 6
10 → 7
11 → 8
4-5 Parity Inhibit 00 → No Parity
01 → Odd parity
10 → No Parity
11 → Even parity
6-7 Stop Bits 00 → Inhibit
01 → 1
10 → 1.5
11 → 2

Mode configuration (Syncronous)

Bit Function Settings
0-1 Not used 00
2-3 Character Length Select Bits:
00 → 5
01 → 6
10 → 7
11 → 8
4-5 Parity Inhibit 00 → No Parity
01 → Odd parity
10 → No Parity
11 → Even parity
6 Sync mode 0 → Internal
1 → External
7 No. of Sync chars 0 → 2 Bytes
1 → 1 Byte

Command register

Bit Function Settings
0 /TXE 0 → Disable
1 → Enable
1 DTR 0 → 1
1 → 0
2 RXE 0 → 0
1 → 1
3 SBRK 0 → Normal Operation
1 → Send BRK char
4 ER 0 → Normal Operation
1 → Reset error flag
5 /RTS 0 → 1
1 → 0
6 IR 0 → Normal Operation
1 → Internal Reset
7 EH 0 → Normal Operation
1 → *

Baud Rate

INFORMATION BELOW IS NOT ACCURATE FOR T200


CPU selection of baud rate is accomplished by loading a divisor into the PIO register through output ports $BC or $B4 and $BD or $B5.

The baud rate selection must be committed by writing $C3 to register $B8.

Here is a table of some baud rates that may be of interest:

Baud Rate PIO
Divisor
Port $BD Port $BC
75 2048 72 0
110 1396 69 116
300 512 66 0
600 256 65 0
1200 128 64 128
2400 64 64 64
4800 32 64 32
9600 16 64 16
19200 8 64 8
38400 4 64 4
76800 4 64 2

I include 76800 since it is the highest baud rate that the M100 is capable of. Certainly they are usable for communicating with another Model 100. However since they are not a "known" baud rate, they are less useful for communicating with PCs or other devices.

That said, you may be able to find a device or bitbang GPIO lines to communicate at these rates. I have read that some USB->Serial adapters are capable of communicating at many more baud rates than the typical built-in serial ports, so there is definitely room for further exploration.

Here is a practical example of using 38400bps using only BASIC code. This program dumps all RAM contents to the serial port.

 1	DEFINTA-Z:
	OPEN"COM:98N1D"FOROUTPUTAS1:
	D$="":
	A=FRE("0"):
	L=VARPTR(D$)+1:
	M=L+1:
	POKEL-1,128:
	OUT180,4:
	OUT181,64:
	OUT184,195:
	FORI=0TO255:
		POKEM,128+I/2:
		POKEL,(IMOD2)*128:
		PRINT#1,D$;:
	NEXT

Unfortunately this BASIC code does not transmit the 32K of data any faster than the 19200bps code. Both take about 33 seconds to transmit the image.

So, here's an assembly language version of the same program. It transfers your Model 100's 32K RAM to a serial connection in about 8.5 seconds!

Note that this code obeys the "clear to send" signal from the PC, so given hardware flow control enabled and properly configured on the PC, we should not overrun the remote UART.

Not that if the PC is busy doing something else (like printing to the screen) it might flow control us, and you may not achieve the maximum speed.

		.org	64704

		; select RS232 port
		MVI	A, $25
		OUT	$BA

		; set up 8N1
		MVI	A, 28
		OUT	$D8

		; set up 38400 bps
		MVI	A, 64
		OUT	$BD
		MVI	A, 4
		OUT	$BC
		MVI	A, $C3
		OUT	$B8

		LXI	H,32768

WAITEMPTY:	IN	$D8
		ANI	$10
		JZ	WAITEMPTY

WAITCTS:	IN	$BB
		CMA
		ANI	$10
		JZ	WAITCTS
	
		MOV	A,M
		OUT	$C8

		INX	H
		MOV	A,H
		ORA	L

		JNZ	WAITEMPTY

		RET

		.END

Data Transmission

Once configured, sending a character is simply

		MVI	'A'
		OUT	$C8

or, in BASIC,

OUT 200,ASC("A")

In the UART, there is room for two characters: the character currently be transmitted, and the next one. This permits you to ensure there is always one character waiting in the wings.

You should never overflow the transmission buffers. Either do some other work during the "downtime" and/or wait until there is room by polling bit 4 (0x10) of register $D8. The code that follows just does a "busy wait."

WAITEMPTY:	IN	$D8
		ANI	$10
		JZ	WAITEMPTY

When deciding whether the other device is ready to receive you should also consider the Clear To Send (CTS) flow control line described later in this document.

Data Reception

BASIC ROM Interrupt 6.5 Handling

Whenever the UART receives another character, Interrupt 6.5 is signalled. Then, if interrupts are enabled, the CPU stops what it is doing and CALLs location 0x0034 in the BASIC ROM. This code disables further interrupts and jumps to the location 0x6DAC.

The ISR then jumps to vector 0xFE5C (0xF5FC?) in RAM. Normally this is just a return instruction, but you could hook the interrupt here. [ stack manipulation to avoid/ or include default processing + re-enable interrupts? - TBD ]

Polling Interrupt 6.5

Accepting the BASIC ROM's handling imposes significant overhead. With each interrupt, the instruction pointer must be placed on the stack and a jump performed at minimum. If the BASIC ROM (as opposed to an Option ROM) is switched in, then you will have the overhead of disabling interrupts, a jump to the DR vector, a return instruction, and then the default processing of reading and enqueing the new character. All that, and at this point no useful work has been performed other than to relieve the UART.

For maximum efficiency you may wish to poll Interrupt 6.5 pin rather than accept the overhead of an interrupt. This is made possible by the 8085's SIM and RIM instructions.

Using the SIM instruction, you can set the interrupt mask such that UART DR (data ready), bit 1, will not trigger an interrupt. Then, you can poll this bit using the RIM instruction ANDing with 0x20 to see if DR is set.

Alternatively, you could disable interrupt processing altogether during your polled routine, but still use RIM to poll. This has the disadvantage of disabling the background ISR. But to achieve higher baud rates, you may not want the background ISR running anyway.

Flow Control

The Model T has full support in hardware for the CTS and RTS flow control lines. In the BASIC ROM, however, it is not implemented. Instead the BASIC ROM relies on slow, kludgy XON/XOFF character escapes. This makes it difficult to transmit or receive binary files since the XON/XOFF characters are reserved for flow control.

Since we are discussing direct control of the UART, we can do better and implement full flow control.

Detect Clear to Send (CTS)

The CTS line is an input to the Model 100. It indicates whether the device attached to the serial port (or the remote equipment behind it) has room to accept new characters. The device can "flow off" the Model T when its receive buffers are full.

Implementing CTS is easy. The following code performs a busy wait on CTS:

WAITCTS:	IN	$BB
		CMA
		ANI	$10
		JZ	WAITCTS

CTS line is read from bit #5 of I/O address 0xBB. Note that it is inverted; if it is 0, the device is signalling "clear to send." If 1, the device is attempting to flow us off from transmitting.

Request Peer to Send (RTS)

The RTS line is an output from the Model 100 to the device connected on the serial port. It is a signal "requesting" the device to send (or not to send). From the other point of view, the device should transmit if and only if RTS is high. Note that from the device perspective, it sees our RTS as its CTS.

If the device implements hardware flow control, it will not send if our RTS (and probably DTR) signals are low. So, at least we will want to set these two bits.

The RTS and DTR lines are located on I/O register 0xBA (186).

(IN PROGRESS)

Handling Communication Errors

(IN PROGRESS)

I/O Map

Here, for reference, is the serial I/O map:

NameDirectionPort
TX Output $C8 (200)
RX Input $C8 (200)
RTS Output $BA (186), bit 7
CTS Input $BB (187), bit 4
DSR Input $BB (187), bit 5
DTR Output $BA (186), bit 6

nb: sense on DSR, CTS seem to be inverted. So CTS ==0 means that it is OK to transmit. A '1' means the device is flowing the Model T off.

nb: Port $BA is called "Port B" in the Model 100 Technical Reference. It has other functions than UART control, including the critical Power On/Off line. See Model 100 Port B for the breakdown.

Direction indicates both data flow, and whether to use an IN or OUT instruction to read/write to the given pin.